BAL-40 windows and doors are glazed openings built to the construction rules for the second-highest bushfire attack level in AS 3959. In practice that means metal frames and hardware, at least 6 mm toughened glass, corrosion-resistant screens with fine mesh, and seals that resist ignition. It also means paperwork that proves the product does what it says. This guide walks you through what each part means, how to check a product before you buy, and what to think about for a new build versus a retrofit.
We supply aluminium windows and doors Australia-wide, so we talk to builders and homeowners about BAL ratings every week. The most common mistake we see is people choosing a window for its look and thinking about the rating afterwards. Flip that order and the whole project gets easier.
What a BAL-40 rating actually means
BAL stands for Bushfire Attack Level. It is a way of measuring how severely a building site could be exposed to a bushfire, and it sets the construction standard the building has to meet. The Western Australian Government describes BAL-40 as very high risk, with increasing ember attack and burning debris, increasing heat flux and a greater likelihood of exposure to flames. Only BAL-FZ (Flame Zone) sits above it.
The rating is not a postcode lottery. It comes from a site-specific assessment under AS 3959 that looks at slope, the type of surrounding vegetation and how far that vegetation is from the building. Two neighbours can end up with different ratings because one block faces a gully and the other faces a paddock.
That assessment is typically done by a BAL assessor, and the WA guidance suggests using an accredited one. Your local council or building certifier will usually tell you whether your land is in a designated bushfire-prone area, and the assessment result then goes into your plans.
Why windows and doors get so much attention
Glass and openings are the weak points of a building in a bushfire. CSIRO notes that the vulnerability of windows and doors often comes from gaps or poor sealing that let embers into the building, so durable, non-combustible materials matter as much as the glass itself. A well-made frame that does not close tightly can let you down, and so can a perfect window with a bad seal.
What BAL-40 requires for windows
Under the deemed-to-satisfy provisions of AS 3959:2018 for BAL-40, as summarised by Clarence City Council’s BAL-40 specification sheet, a window must have:
- a metal frame and metal hardware
- toughened glass at least 6 mm thick
- a screen that meets the screen requirements below, where the window relies on one
The same specification says windows and doors must either use compliant bushfire shutters or meet their listed construction requirements. So you have two paths: protect the opening with a compliant shutter, or build the opening itself to the prescribed detail.
This is one reason aluminium is such a common choice in bushfire zones. Timber can be built to bushfire standards in some situations, but aluminium frames and hardware already meet the metal requirement, and they stay stable and low-maintenance in harsh sun and weather. If you are weighing the two materials for a wider renovation, our page on when it is time to replace your windows and doors covers the signs worth looking for.
What BAL-40 requires for doors
Glazed doors follow the same glass rule: 6 mm toughened glass. The frame and hardware requirements then vary with the door type, as the Clarence specification sets out for each style. That matters because a sliding door, a hinged door and a bifold behave very differently when they are closed under pressure from heat and embers.
Here is how the common door styles compare when you are thinking about bushfire exposure:
| Door style | What to think about at BAL-40 |
|---|---|
| Sliding | Fewer moving parts and a tight track line; check the seal at the meeting stiles and the screen arrangement |
| Hinged and French | Compression seals can be good, but check the hardware material and the threshold detail |
| Bifold and stacking | Many panels mean many joints; ask for evidence that the whole assembly has been assessed |
| Entrance | Solid or glazed leaf, check every glazed part against the glass rule |
That last point on bifolds is where we spend the most time with customers. Bifolds are popular because they open a whole wall to the garden, but each additional panel adds seals and hardware that need to hold up. It is a good reason to ask for documentation, not just a brochure line. You can browse our aluminium doors range, including sliding, bifold, French and stacking options, and ask us which ones are available with bushfire-rated specifications.
Screens, seals and hardware: the small parts that decide compliance
People often think of BAL-40 as a glass question. The listed requirements in the Clarence specification show it is a whole-opening question:
- Screens: corrosion-resistant steel or bronze mesh with a maximum aperture of 2 mm, in a metal frame.
- Seals: a flammability index no greater than 5, or silicone.
- Frames and hardware: metal for windows, and varying by type for doors.
- Glass: 6 mm toughened as a minimum.
Standard insect mesh does not meet the screen requirement. If you are used to ordering flyscreens for comfort, this is a different product. Our flydoors and flyscreen mesh page shows what we offer, and it is worth telling us your BAL rating up front so we can talk through the right mesh and frame.
Seals and installation sealants
The seals built into the window are only part of the picture. The gap between the frame and the wall is another path for embers, and the CSIRO point about gaps applies directly there. Whatever you use to seal the perimeter, check its data sheet for fire performance rather than assuming. A weather-resistant window sealant is a good example of the kind of product to look up: read the technical sheet, then confirm with your builder or certifier that the sealant suits your BAL and your wall construction.
Do you need a tested system or a prescribed build?
This is the question that confuses people most, because suppliers use the words differently. The Clarence specification lists compliant shutters or prescribed construction requirements for windows and doors, and it does not itself state that a complete system has to be tested or certified. That is the deemed-to-satisfy route: you follow the listed recipe.
Many manufacturers go the other way and test whole window or door assemblies to the Australian bushfire test methods, then supply the result. Either way, you want evidence. The Australian Glass and Window Association’s compliance guide says proof can include a declaration of conformity or an AS 1530.8.1 or AS 1530.8.2 test report, along with a visual check that the windows match the requirements.
For houses (Class 1 buildings) and their associated Class 10a buildings or decks in designated bushfire-prone areas, the NCC 2019 deemed-to-satisfy path points to AS 3959 or the NASH steel-framed bushfire standard. Your certifier decides which applies on your project, so ask early.

How to check a BAL-40 product before you pay
Use this short checklist with any supplier, including us:
- Give them your BAL rating in writing. Include the assessment report if you have it.
- Ask which route the product follows. Is it built to the prescribed requirements, or tested as an assembly?
- Ask for the evidence. A declaration of conformity or test report, as described above.
- Confirm the screen. Mesh material, aperture and frame for your exact window or door.
- Confirm the glass. Toughened, at least 6 mm, for every glazed part.
- Match the paperwork to the delivered product. Do a visual check when it arrives, before installation.
- Show the documents to your certifier. They sign off the build, not the supplier.
Our regulations page is a handy starting point if you want to see how we think about standards and compliance across our range.
New build or retrofit: what changes
New builds
On a new build the best time to fix the glazing specification is before the plans are finalised. Your BAL rating drives the windows, doors, screens and often the wall and deck details around them. If the plans call for a large bifold wall and then you learn the rating limits your options, you end up redrawing. Share the rating with your designer on day one.
There is a happy side effect here. Many homeowners building new also want strong energy performance, and bushfire glazing and thermal glazing can work together. Aluminium frames with a thermal break and double glazing are well established, and we cover how that works on our function page. If you are choosing frame colours and styles at the same time, our design page is a good place to compare looks.
Retrofits
For an existing home, FPA Australia’s guidance is to tell your tradespeople the home’s BAL rating and consult a qualified builder, because unsuitable products or modifications can affect bushfire protection or compliance. Practical points we would add from what customers ask:
- Replace the weakest openings first, usually large glazed doors and windows facing the likeliest fire approach, but get your builder’s view on which those are.
- Check the frame-to-wall gap and the sealant, not only the window.
- Do not assume that a new window automatically changes your home’s overall rating. The rating belongs to the site assessment, and the construction has to suit it.
- If your renovation needs approval, speak to your certifier before ordering.
The Standards Australia news item on its new bushfire handbooks for practitioners and homeowners says they give practical guidance that complements AS 3959, which is useful reading alongside your certifier’s advice.
Keeping BAL-40 windows and doors working
A rated product only performs as rated when it is in good condition. FPA Australia notes that BAL ratings assume windows and doors are closed and intact, with regular maintenance. CSIRO adds that keeping them free of flammable debris and closed during a bushfire helps stop smoke and embers getting in.
That translates into a few easy habits:
- Clear leaves and debris from tracks, sills and screen frames.
- Check that sliding and hinged doors close fully and latch properly.
- Look at seals every year and replace any that are cracked or lifting.
- Repair damaged screens rather than patching them with ordinary mesh.
- Close windows and doors when fire danger is high.
It is the kind of maintenance that takes minutes, and it keeps the rating meaningful.
Bushfire-rated aluminium from Simply Doors & Windows
We supply aluminium windows and doors direct to homeowners, builders and renovators across Australia at wholesale pricing, with a wide choice of configurations, colours and glass options, and bushfire-rated features available. Tell us your BAL rating and the openings you are planning, and we will help you work out which products suit, and what documentation to ask for. You can start from our aluminium windows range or aluminium doors range.
For wide openings to the garden, many customers look at our 4 panel aluminium stacking bifold doors. For a front entry, see our aluminium entrance doors. Whichever you choose, confirm the BAL-40 specification with us before you order, so the product, the documents and your certifier all agree.
Common mistakes to avoid
- Choosing on looks, then checking the rating. Do it the other way round.
- Assuming any toughened glass is enough. The whole opening has to meet the requirements: frame, hardware, screen and seals too.
- Using ordinary flyscreens. BAL-40 screens have a specified mesh material and maximum aperture.
- Forgetting the installation gap. Embers find gaps.
- Skipping the paperwork. Keep the declaration of conformity or test report with your build file.
- Treating the rating as fixed forever. If vegetation or land use changes around you, ask your council or assessor whether a new assessment is wise.
Frequently asked questions
Is BAL-40 the same as BAL-FZ?
No. BAL-40 is very high risk, with ember attack, burning debris, heat and a likelihood of exposure to flames. BAL-FZ (Flame Zone) is the highest level and carries stricter requirements again. Your assessment tells you which one applies to your site.
Do BAL-40 windows have to be double glazed?
The listed requirement is toughened glass of at least 6 mm, not a specific double glazing rule. Double glazing is a separate choice for comfort and energy performance. If you want both, ask the supplier to confirm that the full double glazed unit meets the BAL-40 requirements and to give you the supporting documents.
Can I use my existing windows on a BAL-40 site?
Only if they meet the construction requirements for your rating, which usually means metal frames and hardware, 6 mm toughened glass, compliant screens and seals. Many older homes fall short. Ask a qualified builder or your certifier to check before you assume they are fine.
Who confirms my BAL rating?
The rating comes from a site assessment under AS 3959, normally by a BAL assessor, and the WA Government suggests using an accredited one. Your council or certifier can tell you whether your land is in a bushfire-prone area and what they need to see.
What evidence should come with a BAL-40 window or door?
Ask for a declaration of conformity or an AS 1530.8.1 or AS 1530.8.2 test report, and check the delivered product against it. Show the documents to your certifier before installation.